General ordering data
Type CP DC UPS 24V 20A/10A
Order No. 1370050010
Version UPS control unit
GTIN (EAN) 4050118202335
Qty. 1 pc(s).
Dimensions and weights
Width 66 mm
Width (inches) 2.598 inch
Height 130 mm
Height (inches) 5.118 inch
Depth 150 mm
Depth (inches) 5.905 inch
Net weight 1,146 Kg
Temperatures
Humidity 5...95 %, no condensation
Operating temperature, max. 70 °C
Operating temperature, min. -25 °C
Storage temperature, max. 85 °C
Storage temperature, min. -40 °C
Operating temperature -25 °C...70 °C
Storage temperature -40 °C...85 °C
Battery module
Parallel connection option yes, max 2.
Rated voltage 24 V
Storage medium 1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, Selectable with rotary switch
Integrated battery charger
Battery availability test every minute
Charging current 0.15 CA
Charging feature IU characteristic curve
Charging voltage (temperature compensated) 27, 48 V @ 20°C
Temperature coefficient - 48 mV / °C
Operating interfaces and control inputs
DIP switch Inversion of transistor outputs, Operation without temperature probe
Output current selector switch 20 A, 10 A
Remote disconnection (Interlock) Yes
Selector switch battery 1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, No Battery, Service
Selector switch buffer times 0.5 min, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, 45 min, ?, ? w/0
Temperature probe NTC 100 k?
Input
DC current consumption max. 200 mA (without battery), max. 0.5 A (with fully charged battery)
DC input voltage range 20...30 V DC
Input current ? 13A (for 10A), ? 23A (for 20A)
Input fuse (internal) Yes
Max. approved input current 28 A
Rated input voltage 24 V DC
Wire connection method Screw connection
output
Continuous output current @ URated 24 A @ 45 °C, 20 A @ 60 °C, 15 A @ 70 °C
Output current, max. 24 A
Output voltage Vo = Vin - 0.2 V normal operation (Imax), Vo = Vin - 0.3 V battery operation (Imax)
Overload protection Yes
Parallel connection option yes, max 2., Yes, with diode module
Power reserve at nom. voltage 24 A for 1 min, ED = 5 %
Protection against inverse voltage Yes
Rated (nominal) output current @ UNom 20 A @ 60 °C
Rated output voltage 24 V DC ± 1 %
Residual ripple, breaking spikes < 50 mVSS @ 24 V DC, IN
Temperature coefficient - 48 mV / °C
Temperature probe NTC 100 k?
Wire connection method Screw connection
General data
Buffer times Depending on the connected battery
Clip-in foot metal
Current limiting > 120 % IN
Degree of efficiency ? 96% normal mode, battery is being charged, ? 98% normal mode, battery is charged, ? 98% buffer mode
Housing version Metal, corrosion resistant
Humidity 5...95 %, no condensation
MTBF > 500,000 h acc. to IEC 1709 (SN29500
Mounting position, installation notice Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Operating temperature -25 °C...70 °C
Power loss < 10 W
Protection against reverse voltages from the load 32…34 V DC
Protection degree IP20
Short-circuit protection Yes
Storage medium 1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, Selectable with rotary switch
Surge voltage category III
EMC / shock / vibration
Noise emission acc. to EN55022 Class B
Vibration resistance IEC 60068-2-6 2.3 g
Interference immunity test acc. to EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips)
Shock resistance IEC 60068-2-27 30 g in all directions
Основные